PVC, rigid (uPVC) vs PVDF (polyvinylidene fluoride)

Every value below is a typical room-temperature figure with its source, test method and conditions — the same dataset that drives the calculators.

PVC, rigid (uPVC) in fullPVDF (polyvinylidene fluoride) in full← All materials
PropertyPVC, rigid (uPVC)PVDF (polyvinylidene fluoride)Difference
Density1.4 g/cm³1.78 g/cm³PVDF (polyvinylidene fluoride) — 27% higher
Young's modulus E3 GPa2 GPaPVC, rigid (uPVC) — 50% higher
Tensile strength48 MPa45 MPaPVC, rigid (uPVC) — 7% higher
Glass transition Tg82 °C-35 °CPVC, rigid (uPVC) — 117 °C higher
  • Callister & Rethwisch, Materials Science and Engineering, 10th ed.
  • CAMPUS plastics database — typical grade datasheet values (campusplastics.com)

Typical room-temperature values for learning and preliminary design; grades vary widely and a supplier datasheet always overrides a textbook figure. Confirm against the datasheet before design work.