Polysulfone (PSU) vs PVC, rigid (uPVC)

Every value below is a typical room-temperature figure with its source, test method and conditions — the same dataset that drives the calculators.

Polysulfone (PSU) in fullPVC, rigid (uPVC) in full← All materials
PropertyPolysulfone (PSU)PVC, rigid (uPVC)Difference
Density1.24 g/cm³1.4 g/cm³PVC, rigid (uPVC) — 13% higher
Young's modulus E2.5 GPa3 GPaPVC, rigid (uPVC) — 20% higher
Tensile strength70 MPa48 MPaPolysulfone (PSU) — 46% higher
Glass transition Tg185 °C82 °CPolysulfone (PSU) — 103 °C higher
  • CAMPUS plastics database — typical grade datasheet values (campusplastics.com)
  • Callister & Rethwisch, Materials Science and Engineering, 10th ed.

Typical room-temperature values for learning and preliminary design; grades vary widely and a supplier datasheet always overrides a textbook figure. Confirm against the datasheet before design work.