Polyamide 12 (PA12, Nylon 12) vs Polysulfone (PSU)

Every value below is a typical room-temperature figure with its source, test method and conditions — the same dataset that drives the calculators.

Polyamide 12 (PA12, Nylon 12) in fullPolysulfone (PSU) in full← All materials
PropertyPolyamide 12 (PA12, Nylon 12)Polysulfone (PSU)Difference
Density1.01 g/cm³1.24 g/cm³Polysulfone (PSU) — 23% higher
Young's modulus E1.4 GPa2.5 GPaPolysulfone (PSU) — 79% higher
Tensile strength50 MPa70 MPaPolysulfone (PSU) — 40% higher
Glass transition Tg45 °C185 °CPolysulfone (PSU) — 140 °C higher
  • CAMPUS plastics database — typical grade datasheet values (campusplastics.com)

Typical room-temperature values for learning and preliminary design; grades vary widely and a supplier datasheet always overrides a textbook figure. Confirm against the datasheet before design work.